EchoSpan® is an ultrasonic liquid level transmitter produced by Flowline, Inc. It is easy to install and use.
This document provides basic mounting, setup, and use instructions for the EchoSpan ultrasonic liquid level transmitter, covering the LU81, LU83, and LU84 series. It includes guidance on selecting appropriate tank adapters, risers, and stand-pipes to ensure accurate measurements and optimal performance.
| Wiring Voltage | 12-28 VDC |
|---|---|
| Output Current | 4-20 mA |
| Mounting Orientation | Perpendicular to liquid surface |
The sensor displays information in inches, feet, centimeters, meters, or percentage.
The cable minimum is 0.170" (4.3mm) and the maximum is 0.450" (11.4mm).
2" diameter risers should be no taller than 5" and larger diameter risers should be no taller than 12".
The minimum diameter of the pipe is 3".