Key facts
- Brand
- Cognex
- Model
- DMA-EZCCM-001
- Documents
- 3
- Languages
- EN
- Last added
- 2023-10-17
Start here

Cognex DMA-EZCCM-001 User Guide
The DMA-EZCCM-001 is a communication module designed for Cognex DataMan barcode readers, supporting daisy chaining over Industrial Ethernet. It features dual Ethernet ports, an integrated switch, and multiprotocol support for EtherNet/IP™ and PROFINET IO. The module includes LED diagnostics, safety features, and a web server for configuration. It is developed in cooperation with Turck and is suitable for industrial automation environments.
This guide covers setup, connection, triggering, reading results, troubleshooting, maintenance, and firmware updates. It includes detailed instructions for connecting to PLCs, configuring IP addresses, and using the web GUI. Safety and compliance information is also provided.
Cognex DMA-EZCCM-001 specifications
| Transmission Speed | 10 Mbps/100 Mbps |
|---|---|
| Degree of Protection | IP65/P67/PE9K |
| Ethernet Ports | 2x MB, 4-pole |
| DataMan Readers Supported | DataMan 70, 150, 260, 360, 370, 470 Series |
Source: Cognex DMA-EZCCM-001 User Guide
All Cognex DMA-EZCCM-001 documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What protocols does the DMA-EZCCM-001 support?
It supports EtherNet/IP™ and PROFINET IO protocols.
What is the degree of protection for the module?
It has IP65/P67/PE9K protection.
What readers can be connected to the DMA-EZCCM-001?
It supports DataMan 70, 150, 260, 360, and 470 Series readers.
What is the degree of protection for the module?
It has IP65/P67/PE9K protection.
Which DataMan readers are supported?
The device supports DataMan 70, 150, 260, 360, 370, and 470 Series readers.
What is the default IP address?
The default IP address for the webserver is 192.168.1.254.