Start here

Applied Biosystems 7900HT qPCR Instrument Quick Start Guide
This document is a quick start guide for the Applied Biosystems 7900HT qPCR instrument. It explains how to switch on the instrument, open the SDS software, create a new document, select the plate type and template, import files from the Hamilton robot, and start a run.
After the run, the guide covers analyzing amplification plots, checking thresholds and baselines, reviewing melting curves for SYBR green, detecting issues with the QC summary, exporting data to text files, and performing absolute or relative quantification including delta delta Ct.
Applied Biosystems 7900HT specifications
| Reaction volume for 384-well plate | 10ul |
|---|---|
| Reaction volume for 96-well plate | 15ul |
| SDS software platform | PC only |
| Detection channels | FAM/SYBR, rox, background |
Source: Applied Biosystems 7900HT qPCR Instrument Quick Start Guide
All Applied Biosystems 7900HT documents by type
The shortest path to a working setup, usually only a few pages.
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Disassembly, diagnostics and part numbers, for repair.
Questions answered in these manuals
Can SYBR SELECT mastermix be used with this instrument?
No, mastermixes containing high SYBR concentration such as SYBR SELECT should not be used.
From: Applied Biosystems 7900HT qPCR Instrument Quick Start Guide
What reaction volume is used for a 384-well plate assembled by the Hamilton robot?
Use 10ul reaction volume for a 384-well plate assembled by the Hamilton robot.
From: Applied Biosystems 7900HT qPCR Instrument Quick Start Guide
What is the product name and its stated use?
The ABI PRISM 7900HT is a Sequence Detection System for PCR processes.
What is the stated licensing requirement for PCR use?
A license is required to practice the PCR process.
What operating system familiarity is required for hardware maintenance?
The guide assumes you have familiarity with the Microsoft Windows XP operating system.
From: Applied Biosystems 7900HT Fast Real-Time PCR System Maintenance and Troubleshooting Guide
Where can I find safety guidelines for using this instrument?
Refer to the "Safety and EMC Compliance" section in the Applied Biosystems 7900HT Fast Real-Time PCR System Site Preparation Guide.
From: Applied Biosystems 7900HT Fast Real-Time PCR System Maintenance and Troubleshooting Guide