Operating instructions for the WIKA TR21 miniature resistance thermometer designed for sanitary applications, covering configuration, safety, and…
This document provides operating instructions for the WIKA TR21 miniature resistance thermometer, specifically designed for sanitary applications. It covers the instrument's design, safety requirements, commissioning, configuration using WIKAsoft-TT software, and maintenance procedures. The manual details the detachable connection features of TR21-A and TR21-B variants that allow sensor removal without opening the process.
| Measuring range | -30 ... +150 °C or -30 ... +250 °C |
|---|---|
| Supply voltage (4...20 mA version) | DC 10 ... 30 V |
| Switch-on delay | Max. 4 s |
| Maximum permissible autoclaving conditions | 134 °C, 3 bar abs., 100 % r. h. |
Yes, the detachable connection in the TR21-A and TR21-B variants enables removal of the temperature sensor without having to open the process.
The maximum permissible autoclaving temperature is 134 °C.