WIKA TR21 Manuals

ManualLib has 2 documents for the WIKA TR21 (Industrial Robot): 2 user manuals. Every file can be read online or downloaded as a PDF for free.

User Manual 2

Key facts

Brand
WIKA
Model
TR21
Industry
Industrial
Documents
2
Languages
EN
Last added
2026-11-07

Start here

WIKA TR21 Miniature Resistance Thermometer Operating Instructions

WIKA TR21 Miniature Resistance Thermometer Operating Instructions

User Manual 116 pages · 3.2 MB · EN

This document provides operating instructions for the WIKA TR21 miniature resistance thermometer, specifically designed for sanitary applications. It covers the instrument's design, safety requirements, commissioning, configuration using WIKAsoft-TT software, and maintenance procedures. The manual details the detachable connection features of TR21-A and TR21-B variants that allow sensor removal without opening the process.

Read online

WIKA TR21 specifications

Measuring range-30 ... +150 °C or -30 ... +250 °C
Supply voltage (4...20 mA version)DC 10 ... 30 V
Switch-on delayMax. 4 s
Maximum permissible autoclaving conditions134 °C, 3 bar abs., 100 % r. h.

Source: WIKA TR21 Miniature Resistance Thermometer Operating Instructions

All WIKA TR21 documents by type

User Manual 2

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in these manuals

Can the temperature sensor be removed without opening the process?

Yes, the detachable connection in the TR21-A and TR21-B variants enables removal of the temperature sensor without having to open the process.

From: WIKA TR21 Miniature Resistance Thermometer Operating Instructions

What is the maximum permissible autoclaving temperature?

The maximum permissible autoclaving temperature is 134 °C.

From: WIKA TR21 Miniature Resistance Thermometer Operating Instructions

What is the temperature range for the TR21 thermometer?

The TR21 thermometer measures temperatures from -30°C to +150°C or -30°C to +250°C, depending on the model variant.

From: WIKA TR21 Miniature Resistance Thermometer Operating Instructions

Can the TR21 be autoclaved?

Yes, it can be autoclaved up to 134°C, 3 bar absolute, 100% relative humidity for 20 minutes, up to 50 cycles.

From: WIKA TR21 Miniature Resistance Thermometer Operating Instructions