User manual for the SMD 8243 CQV capacitive liquid level sensor controller, covering USB/I2C communication, commands, calibration, mounting, and material…
This manual describes the SMD 8243 CQV capacitive liquid level sensor controller, including required equipment, control board overview, USB and I2C operating modes, serial and I2C data formats, status bits, and calibration commands.
It also covers connecting and mounting the sensor to a vessel, compatible vessel materials and thickness limits, power options, and empty/full calibration procedures.
| Power supply | 5-24 VDC |
|---|---|
| Barrel plug dimensions | 2.1 mm I.D. x 5.5 mm O.D. x 9.5 mm |
| USB serial baud rate | 115,200 |
| USB serial data bits | 8 |
| USB serial parity | None |
| USB serial stop bits | 1 bit |
| I2C bus speed | 100 kHz |
| I2C slave address | 0x08 |
| Data packet transmission rate | 33-5000 ms |
| Default data packet transmission rate | 500 ms |
| Continuous liquid level output | 0.000-100.000% |
| Vessel relative permittivity range | 2.0-8.0 |
| Maximum vessel material thickness | Relative permittivity / 2.5 mm |
| Output threshold range | 10%-90% |
| Continuous output threshold default | 25% |
| Stepwise output threshold default | 50% |
| Compatible sensor | SMD8244 or equivalent CQV sensor |
| Terminal block connector | Molex 0395021008 |
| USB connector | Mini USB |
115,200.
100 kHz.
0x08.