Silicon Labs Si86xx 1 Mbps digital isolator datasheet: 2.5 kV RMS isolation, 2.5–5.5 V supply, ultra-low power, UL, CSA, VDE and CQC safety certifications.
This is the Si86xx 1 Mbps Data Sheet (Rev. 1.03, July 26, 2021) for Silicon Labs' family of ultra-low-power CMOS digital isolators. The devices support data rates from DC to 1 Mbps, operate from a 2.5 to 5.5 V supply, provide up to 2500 V RMS isolation with a 60-year life at rated working voltage, and use Schmitt trigger inputs plus tri-state outputs with ENABLE. Typical supply current is 1.6 mA per channel at 1 Mbps with a 5 V supply and 1.5 mA per channel with a 2.5 V supply, and transient immunity is 50 kV/µs.
The document covers the ordering guide for industrial-grade ("-I") and automotive-grade ("-A") part numbers, the RF on/off-keying theory of operation, device operation and enable-input logic tables, undervoltage lockout and layout recommendations, electrical specifications, pin descriptions, package outlines, land patterns and top markings. Packages are RoHS-compliant 8-pin and 16-pin SOIC bodies, the temperature range is –40 to 125 °C, and products are safety certified by UL, CSA, VDE and CQC with AEC-Q100 qualification and automotive OPNs available.
| Maximum Data Rate | DC to 1 Mbps |
|---|---|
| Operating Supply Voltage | 2.5 to 5.5 V |
| Isolation Rating | Up to 2500 V RMS |
| Supply Current per Channel (5 V, 1 Mbps) | 1.6 mA (typical) |
| Supply Current per Channel (2.5 V, 1 Mbps) | 1.5 mA (typical) |
| Transient Immunity | 50 kV/µs |
| Operating Temperature Range | –40 to 125 °C |
| Isolation Life | 60 years at rated working voltage |
| Qualification | AEC-Q100 |
| UL Withstand Rating | Up to 5000 V RMS for 1 minute |
| Packages | SOIC-16 wide body, SOIC-16 narrow body, SOIC-8 narrow body |
All products support data rates up to 1 Mbps, and the datasheet describes operation from DC to 1 Mbps.
The devices have a wide operating supply voltage of 2.5 to 5.5 V.
All products are safety certified by UL, CSA, VDE and CQC, with withstand ratings up to 2.5 kV RMS.
No. The datasheet lists no start-up initialization required as a key feature.
Yes, automotive grade is available for certain part numbers, and automotive OPNs are listed in the ordering guide.