MTL 9109-22 instruction manual for a 4-segment redundant FISCO fieldbus power supply system, covering safety, installation, testing and ATEX information.
The MTL 9109-22 is a 4-segment, redundant FISCO power supply system for Foundation fieldbus systems in hazardous areas. It powers each intrinsically safe fieldbus segment with a redundant pair of pluggable FISCO power supply modules operating in active/hot standby mode, with duplicated Supply Arbitration Modules (SAMs).
This instruction manual (INM9109 Rev 3) covers general safety information, description and architecture, module carrier and redundant host power, installation and electrical connections, testing and fault finding, module replacement, and ATEX certification information.
| Number of segments | 4 |
|---|---|
| Power module redundancy | Redundant pair per segment |
| Operating mode | Active/hot standby |
| Intrinsic safety standard | IEC 60079-27 (FISCO) |
| Gas group | IIB |
It provides an intrinsically safe field network for Foundation fieldbus systems in hazardous areas.
The field circuit is automatically transferred to the standby module.
Supply Arbitration Modules (SAMs) monitor the health of the FISCO power supplies while maintaining intrinsic safety requirements.
The related datasheet lists IIB Gas Groups.