Lennox SLP99UHV Gas Furnace Service Manual

Service manual for Lennox SLP99UHV series high-efficiency gas furnaces, covering specifications, installation, start-up, maintenance, and wiring.


Lennox SLP99UHV Gas Furnace Service Manual - cover page
Brand
Lennox
Category
Heater
Document type
Service Manual
Language
English
Pages
83
File format
PDF
File size
4.1 MB
Published
22 November, 2026
Updated
22 November, 2026
MD5 checksum
0C7231861548AF1FA5D5063580F1921B

About this manual

This Lennox service literature covers the SLP99UHV series of high-efficiency upflow gas furnaces designed for direct vent (dual pipe) venting systems. The units are equipped with a variable capacity gas valve, variable speed combustion air inducer, and variable speed indoor blower motor.

SLP99UHV models provide heating capacities from 66,000 to 132,000 Btuh and cooling applications from 2 to 5 tons. The manual includes specifications, optional accessories, blower data, unit components, communicating thermostat information, placement and installation, start-up, service checks, maintenance, and wiring diagrams.

What's inside

  • Specifications
  • Optional Accessories
  • Blower Data
  • Unit Components
  • Communicating Thermostat
  • Placement and Installation
  • Start Up
  • Heating System Service Checks
  • Maintenance
  • Wiring and Sequence of Operation

Specifications

Heating capacity66,000 to 132,000 Btuh
Cooling application2 to 5 tons
Maximum input66,000 Btuh
Electrical supply120 volts, 60 hertz, 1 phase
Gas pipe size1/2 in. IPS

Frequently asked questions

What venting system do SLP99UHV models use?

All models are designed only for direct vent (dual pipe) venting systems.

What heating capacities are available?

Heating capacities range from 66,000 to 132,000 Btuh.

Can the furnace be converted to LPG?

Kits are available for conversion to LPG operation.

What is the minimum blower speed for iHarmony zoning?

The minimum blower speed is 250 cfm.