Lennox ELO183DH series oil furnace installation manual covering dimensions, clearances, combustion air, venting, wiring, start-up, service and troubleshooting.
This Lennox installation manual covers the ELO183DH series oil furnace, including the Elite Series ELO183DH oil furnace units. It gives shipping and packing information, unit dimensions, parts arrangement, and installation requirements for licensed professional technicians.
Topics include combustion and ventilation air, installation clearances, venting and flue connections, supply and return air plenums, oil supply line sizing and connections, leak checks, electrical wiring, unit start-up and adjustments, service, burner control, and troubleshooting.
| Top of cabinet clearance (horizontal) | 3 in (76 mm) |
|---|---|
| Front of cabinet clearance (horizontal) | 24 in (610 mm) |
| Service clearance front (horizontal) | 24 in (610 mm) |
| Flue pipe horizontal clearance | 7 in (178 mm) |
It must be serviced annually by a licensed professional technician or equivalent.
The front of the cabinet requires 24 inches (610 mm) clearance.
Never push the ignition reset button more than one time.