Harmony III Zone Control System is an intelligent control system for home heating and cooling produced by Lennox.
The Lennox Harmony III Zone Control System manages the distribution of conditioned air to as many as four areas or zones in a home. Its main component is a control center that coordinates thermostats, motorized dampers, and Lennox HVAC equipment; it can work with gas furnace or blower coil configurations using variable speed blower motors and single- or two-speed condensing units or heat pumps, with an optional Humiditrol interface.
The homeowner’s manual explains the control center switches and LEDs, thermostat HEAT/COOL/AUTO and fan settings, central (Vacation ON) and zone (Vacation OFF) operation, how zones are planned, and Humiditrol setup with the ComfortSense 7000 thermostat. It also covers thermostat replacement and maintenance and includes a zone information record.
| Zones supported | Up to four zones |
|---|---|
| Thermostat requirement | Off-the-shelf 1-heat/1-cool, non-power-robbing, non-heat pump electronic thermostats |
| Control center switches | Two ON/OFF switches |
| Operating modes | Central mode (Vacation ON) or zone mode (Vacation OFF) |
| Optional accessory | Humiditrol dehumidification accessory |
It manages the distribution of conditioned air to as many as four specific areas or zones in the home.
All zones receive conditioned air at the same time, and the master thermostat in Zone 1 controls heating and cooling for all zones.
Turn each thermostat to OFF, or turn the master thermostat OFF and turn either vacation switch to Vacation ON.
In installer settings, open Humidity Settings, select Dehumidify, set Dehum Mode Setting to Humiditrol, and press Enter.