The Leisai CL42 manual provides specifications, wiring diagrams, parameter settings, and troubleshooting for the digital closed‑loop stepper driver.
About this manual
The CL42 is a digital closed‑loop stepper driver developed by Leisai, featuring a 32‑bit DSP controller, programmable current up to 3 A, and a pulse response up to 200 kHz. It supports 42‑series closed‑loop stepper motors and includes protection functions such as over‑current, over‑voltage, and tracking error detection.
The manual covers electrical and mechanical specifications, detailed interface definitions, DIP‑switch configuration, parameter adjustment via RS‑232, typical application wiring, and warranty information. It also explains LED status indicators and fault‑code handling for easy troubleshooting. This manual is written in Chinese.
What's inside
- Product Overview
- Electrical and Mechanical Specifications
- Interface and Wiring
- DIP Switch Settings
- Parameter Settings
- Typical Application Wiring
- Warranty Terms
Specifications
| Continuous output current | 1 – 2.5 A |
|---|
| Input voltage range | +24 V to +48 V DC |
|---|
| Logic input current | 7 – 20 mA |
|---|
| Maximum pulse frequency | 0 – 200 kHz |
|---|
| Insulation resistance | ≥100 MΩ |
|---|
| Alarm output current | 100 mA |
|---|
| Storage temperature | -20 °C to 65 °C |
|---|
| Weight | ≈280 g |
|---|
| Cooling method | Natural cooling or external heatsink, optional fan |
Frequently asked questions
What input voltage range does the CL42 support?
The driver operates from a DC supply of +24 V to +48 V.
How many fault codes can be stored in the driver?
The CL42 can retain up to 10 of the most recent fault codes in its EEPROM.
How is the driver cooled?
It can be cooled naturally or with an external heatsink; a fan may be added for forced cooling.