Which document do I need?

User Manual

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in Leisai manuals

What is the recommended power supply voltage range for the DM556S?

The driver operates with an input voltage between 20 VDC and 50 VDC.

From: Leisai DM556S Digital Two-Phase Stepper Driver User Manual

What protection functions are built into the driver?

The driver includes over‑voltage, over‑current/short‑circuit protection and an alarm output.

From: Leisai DM556S Digital Two-Phase Stepper Driver User Manual

What input voltage range does the CL42 support?

The driver operates from a DC supply of +24 V to +48 V.

From: Leisai CL42 Digital Closed-Loop Stepper Driver User Manual

How many fault codes can be stored in the driver?

The CL42 can retain up to 10 of the most recent fault codes in its EEPROM.

From: Leisai CL42 Digital Closed-Loop Stepper Driver User Manual

How do I set the output current of the DM422 driver?

The output current is set with DIP switches SW1‑SW3 or via the PC software; the maximum is 2.2 A with a resolution of 0.1 A.

From: Leisai DM422 Digital Two-Phase Stepper Driver User Manual

How do I clear a fault condition?

Turn off the power, check the wiring, then power the driver back on to clear the fault alarm.