Kistler 5073A ICAM Industrial Charge Amplifier Datasheet

Technical specification and user manual for the Kistler 5073A ICAM Industrial Charge Amplifier, designed for piezoelectric sensors in manufacturing.


Kistler 5073A ICAM Industrial Charge Amplifier Datasheet - cover page
Brand
Kistler
Category
Industrial Supply
Document type
Datasheet
Language
English
Pages
6
File format
PDF
File size
1.5 MB
Published
18 October, 2026
Updated
18 October, 2026
MD5 checksum
CE5EF4CB41387B3F5BC57AE626A77572

About this manual

The Kistler 5073A ICAM Industrial Charge Amplifier converts piezoelectric charge signals into output voltages proportional to mechanical input quantities. It is designed for industrial applications, supporting up to four sensors with a wide, variable measuring range and digital control via serial interface. The device features a rugged metal case with IP65 protection and integrates with LabView software for flexible parametrization.

What's inside

  • Description
  • Application
  • Technical Data
  • Accuracy of Measurement
  • Supply
  • Control Signals
  • Connectors
  • General Data
  • LED Indicators
  • Pin Allocation

Specifications

Measuring range I±100 … ±1 000 000 pC
Measuring range II±100 … ±1 000 000 pC
Output voltage0 … ±10 V
Supply voltage18 … 30 VDC
Operating temperature range0 … 60 °C
Baud rate115 200 bps
Weight≈320 g

Frequently asked questions

What is the measuring range of the ICAM 5073A?

The device offers two independent variable measuring ranges per channel, both spanning from ±100 to ±1 000 000 pC.

Can the measuring range be switched online?

Yes, the measuring range can be switched online for each channel via their own digital inputs.

What software is used for parametrization?

The device uses Parametrization Software and a Vi-driver Library for LabView.

Download PDF (1.5 MB)

More Kistler Manuals