GP S-Poly(T) Plus miRNA qPCR Assay B032-V002 User Manual

GP S-Poly(T) Plus miRNA qPCR Assay instructions covering kit contents, storage, Poly(A) tailing and RT, real-time PCR setup, data analysis and troubleshooting.


GP S-Poly(T) Plus miRNA qPCR Assay B032-V002 User Manual - cover page
Brand
GP
Category
Chemical products
Document type
User Manual
Language
Chinese
Pages
5
File format
PDF
File size
461 KB
Published
16 November, 2026
Updated
16 November, 2026
MD5 checksum
93A0D8000067BD2AD9320DA214D677CF

About this manual

This is the Chinese instruction manual for the GP S-Poly(T) Plus miRNA qPCR Assay (B032-V002). It introduces the S-Poly(T) Plus method, which combines Stem-loop and Poly(A) tailing approaches: an S-Poly(T) Plus primer made of 5-7 specific bases and 11 dT reverse-transcribes poly(A) tailed miRNA, and the cDNA is then detected by qPCR with a miRNA-specific upstream primer, a universal downstream primer, a universal TaqMan probe and a hot-start enzyme. The kit is described as covering all mature miRNAs of human, mouse, rat, pig, cow, sheep, zebrafish, chicken and viruses in the miRBase database (V22.0).

The manual lists the kit components for the 20RT/100PCR, 40RT/200PCR and 100RT/500PCR sizes, storage at -20°C with avoidance of repeated freeze-thawing, and the one-step Poly(A) tailing and reverse transcription protocol (37°C 20 min, 42°C 20 min, 75°C 5 min, then 5 min on ice). It also gives the real-time PCR reaction setup and cycling program, data analysis by the ΔΔCt method or relative standard curve method, troubleshooting for three common problems, and two appendices with recommended normalization controls and ROX Reference Dye volumes for different instruments. This manual is written in Chinese.

What's inside

  • 产品介绍
  • 产品特点
  • 制品内容
  • 储存条件
  • 一步PolyA加尾和逆转录反应
  • 荧光定量PCR(Real-Time PCR)
  • Real-time PCR 反应程序
  • 数据分析
  • 问题解答
  • 附录1 常用内参基因

Specifications

储存条件-20°C, avoid repeated freeze-thawing
miRNA coverageAll mature miRNAs of human, mouse, rat, pig, cow, sheep, zebrafish, chicken and viruses in miRBase V22.0
SensitivityAbout 10 times higher on average than Stem-loop methods
Kit sizes20RT/100PCR, 40RT/200PCR, 100RT/500PCR
Probe reporter / quencherFAM reporter, no quencher
Reverse transcription program37°C 20 min, 42°C 20 min, 75°C 5 min, then 5 min on ice
Real-time PCR program95°C 10 min, 1 cycle; 95°C 10 sec, 40 cycles; 60°C 30 sec
Specific amplicon size71-77 bp

Frequently asked questions

How sensitive is the S-Poly(T) Plus method compared with Stem-loop methods?

The manual states that miRNA detection with the S-Poly(T) Plus method is on average 10 times more sensitive than conventional methods such as the Stem-loop method.

Which species and miRNAs does the assay cover?

It covers all mature miRNAs of human, mouse, rat, pig, cow, sheep, zebrafish, chicken and viruses in the miRBase database (V22.0).

How should the kit be stored?

Store at -20°C and avoid repeated freezing and thawing.

What can I do if there is no amplification curve or the Ct value is above 35?

The troubleshooting section lists RNA degradation, inhibitors in the extracted RNA, inactive reverse transcriptase and low target miRNA expression, with steps such as avoiding RNase contamination, changing the RNA extraction kit, keeping the enzyme at -20°C and working on ice, and increasing RNA and cDNA input.

Download PDF (461 KB)

More GP Manuals