Freescale i.MX53 SATA Temperature Sensor Application Note

Freescale application note AN4380 explains how the i.MX53 SATA module measures die temperature through SATA PHY registers and ADC readouts.


Freescale i.MX53 SATA Temperature Sensor Application Note - cover page
Brand
Freescale
Category
Processors
Document type
Application Note
Language
English
Pages
14
File format
PDF
File size
305 KB
Published
18 November, 2026
Updated
18 November, 2026
Model
i.MX53
MD5 checksum
9208462C784ADA87A1BE53C30CA72813

About this manual

This Freescale application note (AN4380 Rev. 0, 10/2011) describes the SATA temperature sensor feature of the i.MX53. It explains that die temperature is measured from voltage differences in internal analog circuitry and converted by an ADC in the SATA PHY block.

The document details the SATA_P0PHYCR and SATA_P0PHYSR registers used to access internal SATA registers, lists the DAC control, resistor tuning, ADC output, and MPLL test registers, and provides pseudocode for reading and writing internal register values. It states that usable temperature data requires sampling voltage data 80 times for each of two sampling modes and applying a formula.

What's inside

  • Introduction
  • SATA Registers Used to Obtain Temperature Data
  • SATA_P0PHYCR (SATA PHY control register)
  • SATA_P0PHYSR (SATA PHY Status Register)
  • Internal SATA PHY Registers Required for Temperature Data Calculation
  • DAC Control Register
  • Resistor Tuning Control Register
  • ADC Output Register
  • MPLL Test Register
  • How to Access Internal SATA Registers Through i.MX SATA Register

Specifications

Internal SATA register address width16 bits
SATA_P0PHYCR write access32-bit write access only
Temperature sampling requirement80 samples each for two sampling modes
DAC Control Register address0x0008
ADC Output Register address0x000A
MPLL Test Register address0x0017
SATA_P0PHYCR i.MX register address0x1000_0178

Frequently asked questions

How is die temperature measured in the i.MX53 SATA module?

The die temperature is measured through voltage differences within the internal analog circuitry and converted by an ADC within the SATA PHY block.

How many samples are needed to obtain usable temperature data?

The voltage data must be sampled 80 times each for two different sampling modes, then applied to the formula.

Which registers are used to access internal SATA registers?

SATA_P0PHYCR and SATA_P0PHYSR are the two registers mapped to the i.MX SATA register locations.

What is SATA_P0PHYSR used for?

It is used to monitor PHY status and is where the base data for temperature calculation is obtained.