DODGE guide for selecting Torque-Arm II and Maxum concentric reducers by horsepower or torque, including service factors, thermal checks and examples.
This DODGE Gearing Reference Guide covers Torque-Arm II and Maxum concentric reducers. It lists features and benefits, nomenclature, easy selection, selection and dimensions, and engineering/technical information.
The guide explains the horsepower and torque selection methods step by step: determining the service factor, calculating equivalent horsepower or torque, calculating the required ratio, choosing unit size and ratio, checking thermal ratings, overhung and thrust loads, variable-speed applications and dimensions. Worked examples cover a centrifugal pump and a sewage disposal scum breaker.
| Instantaneous gear loading limit | 200% of the reducer rating |
|---|---|
| MAXUM size 7 thermal rating without fan at 1750 rpm | 150 horsepower |
| MAXUM size 7 thermal rating with fan at 1750 rpm | 273 horsepower |
| MAXUM size 7 overhung load capacity at 230 rpm | 7,480 pounds |
Multiply the actual horsepower to be transmitted by the service factor.
Divide the high speed shaft rpm by the low speed shaft rpm.
When the actual transmitted horsepower exceeds the thermal rating without a fan, an auxiliary cooling fan is required.
The example uses a service factor of 1.25.