DODGE Torque-Arm II/Maxum Concentric Reducer Gearing Reference Guide

DODGE guide for selecting Torque-Arm II and Maxum concentric reducers by horsepower or torque, including service factors, thermal checks and examples.


DODGE Torque-Arm II/Maxum Concentric Reducer Gearing Reference Guide - cover page
Brand
Dodge
Category
Other
Document type
Product Leaflet
Language
English
Pages
26
File format
PDF
File size
453 KB
Published
16 November, 2026
Updated
16 November, 2026
MD5 checksum
2E3C7D9F53E33064631317F1D330A3C6

About this manual

This DODGE Gearing Reference Guide covers Torque-Arm II and Maxum concentric reducers. It lists features and benefits, nomenclature, easy selection, selection and dimensions, and engineering/technical information.

The guide explains the horsepower and torque selection methods step by step: determining the service factor, calculating equivalent horsepower or torque, calculating the required ratio, choosing unit size and ratio, checking thermal ratings, overhung and thrust loads, variable-speed applications and dimensions. Worked examples cover a centrifugal pump and a sewage disposal scum breaker.

What's inside

  • FEATURES/BENEFITS
  • NOMENCLATURE
  • EASY SELECTION
  • SELECTION/DIMENSIONS
  • ENGINEERING/TECHNICAL
  • Horsepower Method of Selection
  • Torque Method of Selection
  • Examples of Selection

Specifications

Instantaneous gear loading limit200% of the reducer rating
MAXUM size 7 thermal rating without fan at 1750 rpm150 horsepower
MAXUM size 7 thermal rating with fan at 1750 rpm273 horsepower
MAXUM size 7 overhung load capacity at 230 rpm7,480 pounds

Frequently asked questions

How is equivalent horsepower calculated?

Multiply the actual horsepower to be transmitted by the service factor.

How is the required ratio calculated?

Divide the high speed shaft rpm by the low speed shaft rpm.

When is an auxiliary cooling fan required?

When the actual transmitted horsepower exceeds the thermal rating without a fan, an auxiliary cooling fan is required.

What service factor does the example use for centrifugal pumps running over 10 hours per day?

The example uses a service factor of 1.25.