DELTA VENT SA Flashing System for Flange Windows Installation Guide

Installation guide for DELTA VENT SA flashing systems on flange windows, covering strip-in and cut-out methods for corners, sills and backdams.


DELTA VENT SA Flashing System for Flange Windows Installation Guide - cover page
Brand
Delta
Category
Other
Document type
Installation Guide
Language
English
Pages
68
File format
PDF
File size
8.8 MB
Published
17 November, 2026
Updated
17 November, 2026
MD5 checksum
5C6C93D9A39F7E7364686D828BBEFDA1

About this manual

The DELTA-VENT SA Flashing Systems for Flange Windows installation guide from Cosella-Dörken Products, Inc. covers preparation of rough window openings with DELTA-VENT SA water-resistive barrier and air barrier components. It presents step-by-step diagrams for strip-in and cut-out methods, including DELTA-FAS CORNER, flat sill, sloped sill, and backdam options.

The membrane is described as a vapor permeable water-resistive barrier and continuous air barrier, with attention to interface areas to prevent water or air penetration. The guide notes that window manufacturer specifications and project design requirements may vary, and final details remain the responsibility of the design authority.

What's inside

  • Introduction
  • Method Selection Guide
  • Strip-in method for flange windows
  • Cut-out method for flange windows
  • With DELTA-FAS CORNER
  • With flat sill
  • With sloped sill
  • With backdam
  • DELTA Accessories
  • Appendix

Specifications

Primary functionVapor permeable water-resistive barrier and continuous air barrier
NFP A 285 complianceCompliant
Air tightnessASTM E2357
Minimum vertical lap6 in (150 mm)
Sill flashing overlap2 in (50 mm) onto face of wall
Window strapping3/8 in (10 mm)

Frequently asked questions

What is DELTA-VENT SA used for?

It is used as a vapor permeable water-resistive barrier and continuous air barrier around rough window openings.

Which methods are shown for flange windows?

The guide shows strip-in and cut-out methods for flange windows.

What is the minimum vertical lap for DELTA-VENT SA membrane?

The guide calls for a minimum 6 in (150 mm) vertical lap.

How much does DELTA-FLASHING overlap onto the face of the wall at the sill?

It is overlapped 2 in (50 mm) onto the face of the wall to provide sub-sill drainage.