Delta H2.5 / H3 / H3A / H4A / H5A Grid-tie Solar Inverter Operation and Installation Manual

Operation and installation manual for Delta H2.5, H3, H3A, H4A and H5A single-phase grid-tie transformerless solar inverters, covering wiring, power control…


Delta H2.5 / H3 / H3A / H4A / H5A Grid-tie Solar Inverter Operation and Installation Manual - cover page
Brand
Delta
Category
inverter
Document type
User Manual
Language
English
Pages
51
File format
PDF
File size
4.9 MB
Published
10 November, 2026
Updated
10 November, 2026
MD5 checksum
1C996F8356B3A89F9112D99708B1FBFE

About this manual

This manual covers the installation, operation, maintenance and technical data of the Delta H2.5 / H3 / H3A / H4A / H5A grid-tie transformerless solar inverters. The device is a single-phase (L + N + PE) solar inverter that converts DC power from a PV array into single-phase AC to supply loads and feed excess power back to the local grid. It uses a DSP design and does not support off-grid operation.

The manual includes safety warnings, unpacking and package inspection, mounting and wiring instructions (AC grid connection, DC connection from the PV array, and PE connection), start-up and shutdown procedures, optional active/reactive power control and LVRT functions, error messages and troubleshooting, and de-commissioning. Installation and start-up must be carried out by an accredited technician or certified electrician.

What's inside

  • General Information
  • Installation and Wiring
  • Product Overview
  • Installation
  • Wiring
  • Active/Reactive Power Control and LVRT
  • Turning the PV inverter on/off
  • Maintenance
  • Error Message and Trouble Shooting
  • Technical Data

Specifications

Power rating2.5kVA (H2.5), 3kVA (H3/H3A), 4kVA (H4A), 5kVA (H5A)
Maximum efficiency>97.4% (>98.3% @ H5A)
Europe efficiency96.8% (98.0% @ H5A)
Reactive power capabilityCap 0.8 – Ind 0.8
Total harmonic distortion< 3% @ full load
Grid typeSingle-phase (L + N + PE), grid-tie, transformerless
Upstream AC circuit breaker (H5A _222)25A for 5 kVA

Frequently asked questions

Does the inverter support off-grid operation?

No, the manual states that this device does not support off-grid function.

Who is allowed to install the inverter?

Installation and start-up must be carried out by an accredited technician, and installation may only be conducted by certified electricians.

How long does dangerous voltage remain after disconnecting power?

Dangerous voltage is present for 1 minute after disconnecting all sources of power; 5 minutes is recommended for discharging.

Can users open the inverter for repair?

No. The inverter contains no user-serviceable parts, and opening it will void the warranty; repair work should only be carried out by the manufacturer.

Download PDF (4.9 MB)

More Delta Manuals


View all Delta manuals →