Delta F Series (AM-ASP-F) servo press installation and maintenance manual covering safety notices, wiring, installation, inspection and troubleshooting.
This manual for the Delta F Series servo press covers safety notices, warning-label locations, machine system structure and configuration. It also describes power, I/O, Ethernet Modbus TCP and RS-485 wiring, the A/B/Z optical scale connection and regenerative resistor installation.
Installation sections cover lifting and fixing for the different model groups, spindle press-head mounting and fixture limits. Maintenance sections cover periodic inspection, rust prevention and lubrication, pressure inspection and calibration, belt replacement and battery box replacement, followed by common problems and troubleshooting, including the brake release procedure for CE models. This manual is written in Chinese.
| Power supply for AM-ASP-F001/F002/F005/F010 | Single-phase three-wire 220 V 50/60 Hz, 10 A |
|---|---|
| Power supply for AM-ASP-F030/F050 | Three-phase four-wire 220/380 V 50/60 Hz, 30 A |
| Grounding wire | 10 mm² or more |
| Protection rating | IP20 |
| Operating humidity | 0–90% RH, non-condensing |
| Operating altitude | Up to 2,000 m |
| Belt specification for AM-ASP-F001 | 228 mm length; 54 ±10% N standard tension; 49–59 N range; part number 3471978700 |
They use a single-phase three-wire 220 V 50/60 Hz supply rated at 10 A.
The machine has an IP20 protection rating.
The belt is the only spare part component listed in the manual.
Check whether the cable between the HMI and the electrical control box is loose.