The manual provides specifications, installation, wiring, software interface, calibration steps and troubleshooting for the Delta DVP02LC‑SL load cell module.
About this manual
This operating manual describes the DVP02LC‑SL load cell module, a 24‑bit, open‑type device that supports 4‑wire or 6‑wire load cells. It includes safety precautions, mechanical dimensions, terminal layout, and LED indicator functions.
The guide also covers installation on a Delta SV controller, wiring diagrams for power and communication (RS‑232/RS‑485), software configuration, calibration procedures, example applications, and a detailed troubleshooting section with LED status explanations. This manual is written in Chinese.
What's inside
- Load Cell Principle
- DVP02LC‑SL Introduction
- Product Appearance and Parts
- Installation and Wiring
- Function Description
- Software Interface
- Calibration Steps
- Application Examples
- LED Indicator and Troubleshooting
Specifications
| Power supply voltage | 24 VDC (‑15 % ~ +20 %) |
|---|
| Power consumption | 3 W |
|---|
| Maximum supply voltage range | 18 VDC ~ 31.2 VDC |
|---|
| Input signal range | ±40 mVDC |
|---|
| Resolution | 24 bits |
|---|
| Communication interfaces | RS‑232, RS‑485 (Modbus) |
|---|
| Supported sensor wiring | 4‑wire or 6‑wire load cells |
|---|
| Linear error | ≤ 0.02 % |
Frequently asked questions
How should multiple load cells be connected to the module?
When connecting several load cells in parallel, the total impedance must be greater than 40 Ω.