The manual provides specifications, installation, wiring, software interface, calibration steps and troubleshooting for the Delta DVP02LC‑SL load cell module.
This operating manual describes the DVP02LC‑SL load cell module, a 24‑bit, open‑type device that supports 4‑wire or 6‑wire load cells. It includes safety precautions, mechanical dimensions, terminal layout, and LED indicator functions.
The guide also covers installation on a Delta SV controller, wiring diagrams for power and communication (RS‑232/RS‑485), software configuration, calibration procedures, example applications, and a detailed troubleshooting section with LED status explanations. This manual is written in Chinese.
| Power supply voltage | 24 VDC (‑15 % ~ +20 %) |
|---|---|
| Power consumption | 3 W |
| Maximum supply voltage range | 18 VDC ~ 31.2 VDC |
| Input signal range | ±40 mVDC |
| Resolution | 24 bits |
| Communication interfaces | RS‑232, RS‑485 (Modbus) |
| Supported sensor wiring | 4‑wire or 6‑wire load cells |
| Linear error | ≤ 0.02 % |
When connecting several load cells in parallel, the total impedance must be greater than 40 Ω.