Delta 6500/6544 Twist Lock Seat Switch Datasheet

Delta 6500/6544 twist lock seat switches sense operator presence and list specifications, dimensions, part configurations and accessories.


Delta 6500/6544 Twist Lock Seat Switch Datasheet - cover page
Brand
Delta
Category
switch
Document type
Datasheet
Language
English
Pages
5
File format
PDF
File size
453 KB
Published
16 November, 2026
Updated
16 November, 2026
MD5 checksum
2EE9FEE32AB0C567654EB63BB866B25E

About this manual

The Delta 6500/6544 is a twist lock seat switch used to sense operator presence. When a seated operator compresses the seat foam, the switch is actuated. Typical applications listed include construction equipment, material handling equipment, outdoor power equipment, forklifts, rental equipment, agricultural equipment, ATVs and UTVs.

The document covers operation, specifications, environmental ratings, dimensions, available configurations, connection, mounting and accessories. It lists maximum voltage and current ratings, pre-travel, contact resistance, cycle life, temperature ranges, panel thickness and cutout dimensions for the 6500 and 6544 series.

What's inside

  • Operation
  • Specifications
  • Environmental Ratings
  • Dimensions
  • Available Configurations
  • Connection
  • Mounting
  • Accessories

Specifications

Maximum Voltage18 VDC
Maximum Current @ 12-14 VDC3 A
Pre-travel.040-.150 inches
Contact Resistance @ Max Current83.3 mΩ
Cycle Life @ Max LoadInductive 10,000; Resistive 75,000
Installation Temperature60 to 100 °F
Operating/Storage Temperature-20 to +100 °F
Salt Fog ExposureASTM B117, 96 Hours
Recommended Panel Thickness.040-.070
Locking Rotation55°

Frequently asked questions

How is the Delta 6500/6544 seat switch actuated?

When a seated operator compresses the seat foam, the switch is actuated.

What are the maximum voltage and current ratings?

Maximum voltage is 18 VDC, and maximum current at 12-14 VDC is 3 A.

What panel thickness is recommended for mounting?

The recommended panel thickness is .040-.070.

What is the cycle life at maximum load?

At maximum load, cycle life is 10,000 inductive and 75,000 resistive.

Download PDF (453 KB)