4B M800 Elite Speed Switch manual covering installation, wiring, sensor calibration, testing, specifications, troubleshooting, and warranty for models…
The 4B M800 Elite Speed Switch is a solid-state, non-contact underspeed monitor for detecting belt slip, belt underspeed, stop motion, low speed, or zero speed on bucket elevators, conveyors, and rotating machinery. Models M8001V10C and M8002V10C provide alarm and shutdown contacts at different trip percentages and can be programmed with a start-up delay of up to 15 seconds.
The document covers customer safety responsibilities, product overview, specifications, dimensions, installation, standard wiring diagrams, sensor calibration, testing and commissioning, troubleshooting, and product warranty. It also describes the inductive sensing arrangement, tacho output, mounting requirements, and approvals for the M800 Elite.
| Supply | 24 - 240 VAC/VDC multi-voltage universal supply |
|---|---|
| Fusing | Supply to be fused at 5A maximum |
| Speed Range | 10 - 3,600 PPM (pulses per minute) |
| Sensing Range - Ferrous target | 11/32" (9 mm) maximum |
| Sensing Range - Non-ferrous target | 7/32" (6 mm) maximum |
| Operating Temperature | -13°F (-25°C) to 158°F (70°C) |
| Enclosure | Nylon |
| Start Up Delay | User selectable 0 - 15 seconds |
| Trip Points - M8001V10C | 10% alarm and 20% shut down (standard version) |
| Trip Points - M8002V10C | 5% alarm and 10% shut down (special order) |
| Contact Rating | 240 VAC / 30 VDC 2.5 A non-inductive maximum |
| Tacho Output | Opto-isolated to 30 VDC, 100 mA max |
| LED Indicator | Red LED indicates input pulses; green LED shows output state and acts as a calibration aid |
| Cable | 6 feet (2 m), 8 conductor |
| Protection | IP67 dust and water tight (fully encapsulated) |
| Approvals | CSA Class II Division 1 Groups E, F and G (USA & Canada); ATEX & CE versions available (Europe) |
| Conduit Entry | 1/2" NPT |
| Cable Jacket Diameter | 8.3 mm |
It is designed to detect belt slip, belt underspeed, stop motion, low speed, or zero speed on bucket elevators, conveyors, or rotating machinery.
The M8001V10C can alarm at 10% below set speed and shut down at 20% below set speed, while the M8002V10C can alarm at 5% and shut down at 10% below set speed.
No. The unit requires no contact with the shaft and is fully solid state.
The maximum sensing range for a ferrous target is 11/32 inches (9 mm), assuming a 3/4 inch (19 mm) diameter target.