This document is the manual of WDC3NV46C, introducing the specification, usage instructions, installation instructions of WDC3NV46C
The 4B WDC3NV46C is a user-programmable, microprocessor-controlled bucket elevator monitoring system designed to monitor motion, alignment, and temperature. The control unit accepts signals from speed and alignment probes, as well as bearing temperature and plugged chute sensors, to provide alarms and shutdown control when hazardous conditions are detected. The system is housed in a self-contained wall-mounting enclosure, while the sensors are separate items for mounting on the elevator.
| Application | Bucket Elevator Monitoring |
|---|---|
| Control Type | Microprocessor controlled |
| Input Signals | Speed and alignment from elevator buckets or bolts |
| Additional Sensors | Bearing temperature, plugged chute, head pulley alignment |
| Mounting | Self-contained wall-mounting enclosure |
| Probe Input Range | Between one and four probes |
Read all user, instruction, and safety manuals provided with the product to ensure safe and effective operation.
The responsibility lies with the user unless 4B was specifically asked to perform these tasks.
The control unit recognizes the absence of pulses as a misalignment condition, displays the location, and affects an alarm signal which can result in shutdown.
The system accepts signals from between one and four probes mounted on the bucket elevator.