The F500 Elite Fieldbus adapter serves as a communications gateway designed to network up to 7 Watchdog NTC control units together and pass data to a DeviceNet master. The unit is housed in a wall-mounting enclosure and supports both AC and DC power supplies.

This manual covers the technical specifications, electrical wiring, and operating instructions for the adapter, including the configuration of baud rates and MAC addresses via onboard switches.

What's inside

  • INTRODUCTION
  • SPECIFICATIONS
  • INSTALLATION INSTRUCTIONS
  • ELECTRICAL WIRING
  • OPERATING INSTRUCTIONS
  • FAULT FINDING
  • CONTACT INFORMATION
  • DRAWINGS

Specifications

Electrical Supply100 to 230VAC +/- 10% 50/60Hz or 24VDC +/- 10%
Power Consumption12 WATTS
Protection RatingNEMA12, IP65
Dimensions9.7” H x 7.4” W x 4” D (246mm x 188mm x 102mm)
Weight3lbs (1.3Kg)

Frequently asked questions

How is the DeviceNet baud rate configured?

The baud rate is set using switches 1 and 2: OFF/OFF for 125K, ON/OFF for 250K, and OFF/ON for 500K.

What does a steady green LED 2 indicate?

A steady green LED 2 indicates that the link is OK, on line, and connected.

How many Watchdog NTC control units can be networked?

The adapter is designed to allow up to 7 Watchdog NTC control units to be networked together.