User manual for the 4B F500 Elite (NTC) Fieldbus adapter, providing installation, wiring, and configuration for Watchdog Elite to DeviceNet communications.
The F500 Elite Fieldbus adapter serves as a communications gateway designed to network up to 7 Watchdog NTC control units together and pass data to a DeviceNet master. The unit is housed in a wall-mounting enclosure and supports both AC and DC power supplies.
This manual covers the technical specifications, electrical wiring, and operating instructions for the adapter, including the configuration of baud rates and MAC addresses via onboard switches.
| Electrical Supply | 100 to 230VAC +/- 10% 50/60Hz or 24VDC +/- 10% |
|---|---|
| Power Consumption | 12 WATTS |
| Protection Rating | NEMA12, IP65 |
| Dimensions | 9.7” H x 7.4” W x 4” D (246mm x 188mm x 102mm) |
| Weight | 3lbs (1.3Kg) |
The baud rate is set using switches 1 and 2: OFF/OFF for 125K, ON/OFF for 250K, and OFF/ON for 500K.
A steady green LED 2 indicates that the link is OK, on line, and connected.
The adapter is designed to allow up to 7 Watchdog NTC control units to be networked together.