4B M1001V10F Stopswitch Motion Monitor Installation and Operation Manual
This manual provides installation and operation instructions for the 4B M1001V10F Stopswitch, a shaft speed monitoring device that signals when rotation stops. It includes safety guidelines, wiring diagrams, testing procedures, and troubleshooting steps. The device requires no calibration and operates with a 24–240V AC/DC supply, featuring a 4-second startup delay and IP67 protection. Installation must comply with local electrical codes and include a guard for rotating parts.
The manual emphasizes customer safety responsibilities, including proper installation by qualified electricians, regular maintenance, and adherence to OSHA and local codes. It also details wiring configurations, sensor target distances, and LED indicators for input and output states.
Covers: Customer Safety Responsibilities · Product Overview · Specifications · Dimensions · Installation · Standard Wiring Diagram

4B Mag-Con Magnetic Connector Installation and Operation Manual
The 4B Mag-Con is an optional magnetic connector designed to screw onto the Whirligig universal shaft sensor mount. It allows for the secure and simple installation of the Whirligig onto a machine shaft without the need for drilling or tapping. The product is specifically designed to work with 4B's Whirligig system and is not compatible with other manufacturers' products or stainless steel shafts.
Covers: Safety Notice · Customer Safety Responsibilities · Product Overview · Specifications · Installation · Compatible Sensors

4B WDC3NV46C Bucket Elevator Monitoring System Installation and Operation Manual
The 4B WDC3NV46C is a user-programmable, microprocessor-controlled bucket elevator monitoring system designed to monitor motion, alignment, and temperature. The control unit accepts signals from speed and alignment probes, as well as bearing temperature and plugged chute sensors, to provide alarms and shutdown control when hazardous conditions are detected. The system is housed in a self-contained wall-mounting enclosure, while the sensors are separate items for mounting on the elevator.
Covers: Introduction · Installation & Wiring · Operating Instructions · Engineer Adjustable Parameters · Fault Finding · Warning Messages
Latest 4B manuals
4B M1001V10F Stopswitch Motion Monitor Installation and Operation Manual
User Manual 11 pages · 1.1 MB · ENInstallation and operation guide for 4B's M1001V10F Stopswitch, covering safety, specs, wiring, testing, and troubleshooting.
4B Mag-Con Magnetic Connector Installation and Operation Manual
User Manual 8 pages · 929 KB · ENInstallation and operation manual for the 4B Mag-Con magnetic connector, designed for use with the Whirligig target to magnetically couple to machine shafts.
4B WDC3NV46C Bucket Elevator Monitoring System Installation and Operation Manual
User Manual 53 pages · 3.4 MB · ENInstallation and operation manual for the 4B WDC3NV46C Watchdog Control Unit, a microprocessor-controlled monitoring system for bucket elevators.
Which document do I need?
User Manual
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in 4B manuals
What is the sensing range for ferrous targets?
Maximum 5/16 in. (8 mm) for ferrous targets, assuming a 3/4 in. (19 mm) diameter target.
From: 4B M1001V10F Stopswitch Motion Monitor Installation and Operation Manual
What is the output state when the shaft stops rotating?
The output becomes normally open (green LED off) if no input is received for 4 seconds.
From: 4B M1001V10F Stopswitch Motion Monitor Installation and Operation Manual
Is the Mag-Con compatible with stainless steel shafts?
No, the Mag-Con is not compatible with stainless steel shafts as they are non-ferrous metal.
From: 4B Mag-Con Magnetic Connector Installation and Operation Manual
What is the minimum shaft diameter required for the Mag-Con?
The minimum shaft diameter required is 1-7/8 inches.
From: 4B Mag-Con Magnetic Connector Installation and Operation Manual
What safety precautions should be followed before operating the product?
Read all user, instruction, and safety manuals provided with the product to ensure safe and effective operation.
From: 4B WDC3NV46C Bucket Elevator Monitoring System Installation and Operation Manual
Who is responsible for the proper installation and maintenance of the equipment?
The responsibility lies with the user unless 4B was specifically asked to perform these tasks.
From: 4B WDC3NV46C Bucket Elevator Monitoring System Installation and Operation Manual