Dell PowerConnect W-6000 Controller Installation Guide
This installation guide is for trained technicians responsible for installing the Dell PowerConnect W-6000 controller, an enterprise-class modular chassis that connects and controls wireless Access Points (APs) and Air Monitors (AMs) into the wired LAN. It covers mounting the 3U chassis in a standard 19-inch rack, adding W-6000M3 controller modules, connecting power, and performing initial power-on verification tests.
Later chapters describe the fan tray with built-in redundancy and hot-swap support, the W-6000M3 controller module, and the hot-swappable power supply modules with load sharing, including procedures for inserting and removing power supplies. A specifications chapter lists physical, environmental, operational, compliance, EMI and safety information.
| Ethernet switching | 10/100/1000 Mbps and 10 Gbps Ethernet with Layer-2/Layer-3 packet forwarding |
|---|---|
| Chassis height | 3U, mountable in a standard 19-inch telecom or server rack |
| Controller modules | Up to 4 Dell PowerConnect W-6000M3 modules |
| Power supplies | Up to 3 hot-swappable power supplies with load sharing for redundancy |
| Cooling | Fan tray containing three individual fans for redundancy |
| Operating temperature | 0 to 40 ºC (32 to 104 ºF) |
| Power cord requirement | One power cord per power supply, rated to at least 10 A with IEC320 connector |
Installation should be performed by a trained technician, as stated in the manual's precautions.
Leave at least 10 cm (4 inches) of clearance on the left and right of the chassis, and keep the side air vents unobstructed.
No. Verify the power switch is Off and the cord is unplugged before inserting or removing a power supply.
No. Module handles are only for removing and inserting individual modules; using them to support the chassis can damage the module and chassis.