Siemens SITRANS LVL 200S, LVL 200E Safety Manual

The SITRANS LVL 200S, LVL 200E from Siemens is a SIL 2 certified transistor (NPN/PNP). The product is suitable for safety-related applications such as level measurement in the process industry.


Siemens SITRANS LVL 200S, LVL 200E Safety Manual - cover page
Brand
Siemens
Category
sensor
Document type
Other
Language
Spanish
Pages
24
File format
PDF
File size
4.4 MB
Published
24 November, 2023
Updated
24 November, 2023
MD5 checksum
CAD4F09C2B3D8104F5282DFFE568E306

About this manual

This safety manual applies to Siemens SITRANS LVL 200S and LVL 200E vibration level sensors with SIL qualification and a transistor (NPN/PNP) electronic module. It covers the safety function, safe state, operating prerequisites, and safety-related technical parameters for use in safety-related systems according to IEC 61508.

It also describes commissioning adjustments, internal diagnostics and service behavior, periodic proof tests, and annexes including a test protocol, definitions, and SIL conformity. The sensors are intended for level detection in liquids in low demand or high demand mode, up to SIL2 in single-channel and up to SIL3 in multichannel architectures. This manual is written in Spanish.

What's inside

  • Scope of validity
  • Safety function
  • Safe state
  • Operating prerequisites
  • Safety technical parameters
  • Commissioning
  • Diagnostics and service
  • Periodic proof test
  • Annex A test protocol
  • Annex C SIL conformity

Specifications

Electronic moduleTransistor (NPN/PNP)
Safety Integrity Level (single-channel)SIL2
Safety Integrity Level (multichannel)SIL3
Instrument typeType A
Operating modeLow demand mode, High demand mode
MTBF3.61 x 10^6 h (412 years)
PFDAVG (T1 = 1 year)0.025 x 10^-2
PFH0.030 x 10^-6 1/h
MTTFd3805 years
Performance Level3.00 x 10^-8 1/h (corresponds to e)
Safe state outputTransistors non-conductive (no current)
Ambient temperature correction factor1.3 above 50 C; 2.5 above 60 C
Mean time to repair24 h

Frequently asked questions

What safety integrity level can the SITRANS LVL 200S and LVL 200E achieve?

Up to SIL2 in a single-channel architecture and up to SIL3 in a multichannel architecture.

What is the safe state of the sensor outputs?

The transistors are non-conductive (no current).

What must be done if a fault is detected?

Take the entire measuring system out of service and keep the process safe by other measures; report undetected dangerous faults to the manufacturer.

Which periodic proof tests are described?

One test without filling/emptying or removing the sensor and one with filling/emptying or removing the sensor.