Invitrogen Attune Performance Tracking Beads User Guide

The Invitrogen™ Attune™ Performance Tracking Beads (PT Beads) are designed for use with the Attune™ and Attune™ NxT Acoustic Focusing Cytometers. The beads allow the instrument software to automatically characterize, track, and report performance measurements of the cytometer.


Invitrogen Attune Performance Tracking Beads User Guide - cover page
Brand
invitrogen
Category
Chemical products
Document type
User Manual
Language
English
Pages
4
File format
PDF
File size
125 KB
Published
17 November, 2023
Updated
17 November, 2023
MD5 checksum
0E2F34258F7473A97247D7FFD2489BF5

About this manual

Invitrogen Attune Performance Tracking Beads (catalog number 4449754) are designed for use with the Attune and Attune NxT acoustic focusing cytometers. Each vial contains a mixture of four fluorescence emission intensity levels and is sufficient for approximately 50 daily measurements or 50 baseline definitions.

The guide covers baseline calculation, daily performance tracking, bead preparation, dilution instructions, and storage at 2–8°C protected from light. The beads contain 0.05% sodium azide as a preservative and are stable for 1 year when stored as directed.

What's inside

  • Product information
  • Baseline calculation
  • Contents and storage
  • Performance tracking
  • Before you begin
  • Methods
  • Prepare Attune Performance Tracking Beads in tubes
  • References
  • Documentation and support
  • Ordering information

Specifications

Intensity level 1 bead diameter2.4 μm nominal diameter
Intensity levels 2-4 bead diameter3.2 μm nominal diameter
Measurements per vialApproximately 50 daily measurements or 50 baseline definitions
Stability1 year when stored as directed
Storage conditions2–8°C, protect from light, do not freeze
Sodium azide concentration0.05%

Frequently asked questions

Which cytometers are the beads designed for?

They are designed for use with the Attune and Attune NxT acoustic focusing cytometers.

How many daily measurements can one vial perform?

Each vial contains beads sufficient for approximately 50 daily performance measurements or 50 baseline definitions.

How long can diluted bead suspension be stored?

Store the diluted bead suspension at 2°C to 25°C, protected from light, for no more than 4 hours.

What preservative is in the bead solution?

The solution contains 0.05% sodium azide as a preservative.