The SmartSolar MPPT 150/35 and 150/45 is a solar charge controller with the following features: - Automatic battery voltage detection - Excellent MPPT algorithm - Excellent conversion efficiency - Extensive electronic protection - VictronConnect app - Display - VE.Direct port - Charge output - Virtual load output - BatteryLife - Battery charging - 3-step adaptive battery charging process - Flexible charging algorithm - Equalizing charge - Temperature sensor - Internal temperature sensor - External voltage and temperature sensor - Voltage detection - Remote on/off switch - Terminal box
This is the Spanish-language user manual for the Victron SmartSolar MPPT 150/35 and 150/45 solar charge controllers, revision 05 dated September 2023. It begins with general and wiring safety precautions, the symbols used on the enclosure, and FCC and Industry Canada compliance statements for both models.
The manual describes the chargers' features, including automatic battery voltage detection, an MPPT tracking algorithm, the VictronConnect app, the VE.Direct port, a three-stage adaptive battery charging process, temperature sensing and remote on/off control. It then covers installation and wiring, configuration via VictronConnect, the rotary switch or the MPPT Control display, operation including lithium batteries and equalization, LED indications and error codes, extensive troubleshooting sections, and the technical specifications and dimension drawings. This manual is written in Spanish.
| Ingress protection rating | IP43 |
|---|
The electronic components are protected against small tools and wires over 1 mm and against water sprayed at an angle of less than 60 degrees from the vertical.
Flexible multi-stranded copper cable must be used, with each strand having a diameter below 0.4 mm (0.016 inches) or a cross-section below 0.125 mm² (AWG26).
Yes, the manual includes a section on configuration with the VictronConnect app, alongside configuration via the rotary switch and the MPPT Control display.
Yes, the device complies with part 15 of the FCC Rules and with Industry Canada RSS, subject to the two conditions that it may not cause harmful interference and must accept any interference received.