MC119 catalytic combustible gas sensor adopts catalytic combustion principle, and its two arms resistance changes when heated, the change is proportional to the gas concentration. The sensor has the characteristics of high sensitivity, fast response speed, strong anti-interference ability and long service life.
This manual describes the MC119 catalytic flammable gas sensor from Zhengzhou Winsen Electronics Technology Co., Ltd. The sensor works on the catalytic combustion principle: its electric bridge consists of a test element and a compensate element, and the bridge output voltage rises in proportion to the concentration of combustible gases such as methane, hydrogen, ethyne, gasoline and VOCs like alcohol, ketone and benzene.
The document lists the sensor's features and technical parameters, including working voltage, sensitivity, measuring range and response times, and shows characteristic curves for sensitivity, response and recovery, temperature and humidity dependence, and long-term stability. It closes with detailed cautions on conditions to avoid, such as organic silicon steam, corrosive gases, water contact, high voltage, and recommended soldering and storage conditions.
| Working voltage | 2.5±0.1 V |
|---|---|
| Working current | 100±10 mA |
| Sensitivity | 1% H2: 20–40 mV; 1% C2H2: 40–90 mV |
| Linearity | ≤5% |
| Measuring range | 0–100 %LEL |
| Response time (90%) | ≤10 s |
| Recovery time (90%) | ≤30 s |
| Working environment | -40 to +70 °C, less than 95%RH |
| Size | 19×9.5×14 mm |
| Anti-explosion mark | ExdibⅠ |
It is used in industrial settings to detect the concentration of hydrogen, ethyne, gasoline and VOCs such as alcohol, ketone and benzene, and has good sensitivity to methane.
Handmade welding is optimal, using rosin soldering flux with least chlorine, a 250 °C soldering iron for less than 3 seconds. For wave-soldering, the speed should be 1–2 m/min with a warm-up temperature of 100±20 °C and welding temperature of 250±10 °C.
For storage over half a year without power, the suggested aging time is at least 24 hours; for more than one year of storage it needs more than 48 hours.
The drift in air per year is within ±2 mV, and in 1% CH4 it is also within ±2 mV.