ARD Series Single-Phase Elevator Power-Failure Self-Rescue Device User Manual

This document describes the single-phase ARD series elevator emergency self-rescue device, which can help the elevator to operate safely in the event of a power failure.


ARD Series Single-Phase Elevator Power-Failure Self-Rescue Device User Manual - cover page
Category
Other device
Document type
User Manual
Language
Chinese
Pages
10
File format
PDF
File size
494 KB
Published
11 November, 2023
Updated
11 November, 2023
MD5 checksum
79818785ABF8B0A63A67849D529D0082

About this manual

This manual (version V2.6) describes the ARD series single-phase elevator power-failure self-rescue device (停电自救援装置). When the mains supply fails, the device disconnects the elevator system from the grid and, after roughly 13 seconds, generates single-phase AC220V or AC380V power so the elevator can run at self-rescue speed and level to release passengers. A single rescue run lasts up to 5 minutes before the output shuts off automatically.

The manual explains the model numbering system (ARD4S/2S/2D/2E variants with or without battery), the nameplate, standard specifications, product selection tables for motor power and elevator load ratings, mounting dimensions for wall-mounted and floor-standing installation, application wiring diagrams for each series including the ARD4SXX-Z variant, and operation of the panel with its LED indicators, start button, enable switch and 4-digit display. This manual is written in Chinese.

What's inside

  • Product Introduction
  • Model Description
  • Nameplate
  • Standard Specifications
  • Product Selection
  • Dimensions
  • Wiring (ARD4SXX / ARD2SXX / ARD2DXX / ARD2EXX / ARD4SXX-Z)
  • Working Principle
  • Operation Panel
  • LED Indicators

Specifications

Recommended self-rescue speed1/12 of elevator rated speed
Single run time5 min
Output voltage waveformSine wave
Cooling methodNatural / forced air cooling
Protection ratingIP20
Ambient conditions-15~40°C, humidity below 90%RH (non-condensing)
VibrationAbove 1G below 20Hz
Motor power range (380V class)5.5 kW – 37 kW

Frequently asked questions

How soon after a power failure does the ARD device start supplying power?

After the mains supply is cut, the device disconnects the elevator from the grid and produces single-phase AC220V or AC380V output in about 13 seconds.

How long can the device run during one rescue operation?

A single rescue run lasts at most 5 minutes, after which the output is cut off automatically.

What do the display codes C., P., E. and B. mean?

C. means charging (shows battery voltage), P. means normal output (shows output voltage), E. means fault (shows fault code), and B. shows battery level as a percentage.

Which wiring scheme should be used for a control cabinet with a contactor in front of the inverter?

The ARD4SXX-Z scheme is intended for systems where the inverter supply front end has a contactor (emergency-stop or power-on main contactor).