Parker AC30 Profibus DP-V1 Option Technical Manual

The AC30 Profibus DP-V1 Option Technical Manual describes the features and characteristics of the AC30 Profibus DP-V1 option.


Parker AC30 Profibus DP-V1 Option Technical Manual - cover page
Brand
Parker
Category
Communications equipment
Document type
User Manual
Language
English
Pages
38
File format
PDF
File size
1.2 MB
Published
06 November, 2023
Updated
06 November, 2023
MD5 checksum
6934D9C1E91E6B37ECAE9A81D223D235

About this manual

This technical manual covers the Parker AC30 Profibus DP-V1 Option (product code 7003-PB-00). It describes features, installation, Profibus network connection, LED indications, configuration, acyclic data exchange, parameters, troubleshooting, and appendices.

The option supports Profibus DP-V1 communication with up to 12 Mbps transmission, a galvanically isolated bus via a DB9F female connector, up to 152 bytes of cyclic I/O data, up to 68 bytes of Class 1 and Class 2 acyclic data, and up to 152 bytes of configuration data.

What's inside

  • Introduction
  • Installation
  • Connecting to the Profibus Network
  • LEDs
  • Configuration
  • Acyclic Data Exchange
  • Parameters
  • Troubleshooting
  • Appendix A - Array Parameter Numbers
  • Appendix B - Data Types

Specifications

Product code7003-PB-00
Transmission rateUp to 12 Mbps
Bus connectorDB9F female connector
Cyclic I/O dataUp to 152 bytes total
Acyclic dataUp to 68 bytes (Class 1 and Class 2)
Configuration dataUp to 152 bytes

Frequently asked questions

What is the product code of the AC30 Profibus DP-V1 Option?

The product code is 7003-PB-00.

What transmission rate does the option support?

Up to 12 Mbps.

How much cyclic I/O data can the option handle?

Up to a total of 152 bytes.

What is the equipment intended for?

Industrial motor speed control utilising AC induction or AC synchronous machines.