The MP-3722 is a solar charge controller with 3-stage charge control, equalization charging mode (automatic or manual), 12V DC load terminal control mode, temperature sensor (optional) and over temperature protection.
The MP-3722 PV Charge Controller is designed for use with 12V photovoltaic panels/systems and different types of 12V batteries, such as wet or sealed lead acid, lead calcium, and lead antimony batteries. It provides PWM charging with 3-stage charge control, overcharge and over-discharge protection, over-temperature protection, and an informative LCD display with LED indications.
The manual covers connection and installation, LED and LCD indications, dip-switch and button settings, charge control modes, equalization charging, DC load control, and optional temperature sensor and remote signal terminal features.
| Battery voltage | 12V |
|---|---|
| Maximum PV panel open circuit voltage | 26V |
| Continuous load/charge current | 30A |
| Maximum charge current (5 mins) | 35A |
| Maximum load current (5 mins) | 35A |
| Operation current (no Load and no PV) | 15mA |
| Voltage across terminals (PV to Battery) | 1.2V |
| Voltage across terminals (Battery to Load) | 0.6V |
| Electronic Blocking | Yes |
| Battery reverse polarity protection | Yes |
| Overcharge & Over-discharge protection | Yes |
| Battery status LED indication | 5-State LED Indications |
| Charging status indication | 3-State LCD Display |
| Recommended wire size | #10AWG |
| Weight | 0.48kg |
| Dimension (WxDxH) | 150 x 85 x 45 mm |
| Fuse | 40A |
| Operating ambient temperature | -10 to 50 °C |
| Over temperature protection | Yes |
| Battery charging float voltage setting | Adjustable from 12.0-16.5V |
| Battery charging bulk voltage setting | Adjustable from 12.0-16.5V |
| Low Voltage Disconnect (LVD) | Adjustable from 8-16V |
| Low Voltage Reconnect (LVR) | Adjustable from 8-16V |
It is intended to be used with a battery supply of 12 VDC nominal voltage.
The recommended wire size is #10AWG.
The factory preset bulk voltage is 14.3V and the float voltage is 13.5V.
When enabled, equalization charge occurs for 2 hours once every thirty days.