Quick guide for the Studer Variotrack VT 40, VT 65 and VT 80 solar MPPT charge controllers: mounting, wiring, DIP switch configuration and technical data.
This quick guide covers the Studer Variotrack (VT) solar MPPT charge controller in the VT 40, VT 65 and VT 80 versions. Connected to a battery and photovoltaic panels, the VT recharges the battery in an optimum way; the document states that the unit is designed, manufactured, assembled and tested in Studer's factory in Switzerland and has a 10-year warranty.
The guide walks through mounting place, fixing and dimensions, wiring and communication connections, PV and battery connections, protection devices, multi-unit setup and power-up, the display and its indicators, DIP switch configuration and MPPT setting, assembling the cooling fan for the VT 80, maintenance and recycling, and technical data. It also lists the compatible Studer accessories and modules such as the RCC 02/03 remote control, Xtender, Vario, BSP, Xcom CAN and Xcom LAN/GSM.
| Battery nominal voltage | 12/24/48 Vdc |
|---|---|
| Battery charge current | 40 A (VT 40), 65 A (VT 65), 80 A (VT 80) |
| Battery min-max voltage | 17-68 Vdc |
| PV maximum voltage | 150 Voc (75 Voc @ 12Vdc) |
| PV maximum current | 35 A (VT 40), 60 A (VT 65), 75 A (VT 80) |
| Maximum power at 12 V | 625 W (VT 40), 1000 W (VT 65), 1250 W (VT 80) |
| Maximum power at 24 V | 1250 W (VT 40), 2000 W (VT 65), 2500 W (VT 80) |
| Maximum power at 48 V | 2500 W (VT 40), 4000 W (VT 65), 5000 W (VT 80) |
| Protection rating | IP 54, Class I |
| Weight | 3.8 – 5.5 kg |
| Warranty | 10 years |
It is a solar MPPT charge controller. Connected to a battery and photovoltaic panels, it recharges the battery in an optimum way.
Apart from a periodic check of the connections (tightening and general condition), the Variotrack does not require any particular maintenance.
The PV maximum voltage is 150 Voc, or 75 Voc when used with a 12 Vdc battery.
Lithium batteries communicate through the BMS with Xcom CAN; the compatibility list and the Xcom CAN manual should be checked.