About this manual

Phocos CIS-N-MPPT 100/30 is an MPPT solar charge controller described in this multilingual user manual. It features automatic 12/24 V system voltage detection, negative grounding, IP68 enclosure protection, and charging profiles for flooded acid, sealed, and lithium (LiFePO4) batteries.

The manual covers general safety, maintenance and installation, connection and grounding, cable identification, display and warning functions, night light and dimming functions, test and safety functions, and low-voltage disconnect settings. This manual is written in German.

What's inside

  • General safety instructions
  • Maintenance and installation
  • Connection and grounding
  • Cable identification
  • Display and warning functions
  • Night light function
  • Dimming function
  • Test function
  • Safety functions
  • Deep discharge protection (LVD)

Specifications

Enclosure protectionIP68; protected in 1.5 m water depth for 72 hours
System voltage12/24 V with automatic detection
GroundingNegative grounding
Charging profile (flooded acid batteries)4-stage: Main, Boost, Equalization, Float
Charging profile (sealed and lithium batteries)3-stage: Main, Boost, Float
Night light modes3: standard controller, dusk-to-dawn, evening/morning
Dimming output voltage0-10 V relative to battery negative; 1 V steps; 3% deviation
Dimming output impedance1000 ohm
Recommended minimum cable cross-section10 mm²
Maximum PV voltage100 V
MPPT charging stop voltageAbove 95 V
Low-voltage disconnect (voltage-controlled)11.0/22.0 V to 11.9/23.8 V in 0.1/0.2 V steps

Frequently asked questions

How many charging stages are used for flooded acid batteries?

Four stages: Main, Boost, Equalization, and Float.

How many charging stages are used for sealed and lithium batteries?

Three stages: Main, Boost, and Float.

Does the controller detect system voltage automatically?

Yes, it automatically detects 12 V or 24 V system voltage.

What is the enclosure protection rating?

IP68, protected in 1.5 m water depth for 72 hours.