ELC EVR-GHLC-3P/EVR-GHLC-3PP Three-Phase Intelligent Voltage Meter User Manual

This document is the instruction manual for three-phase intelligent voltage meter, which introduces the basic function, technical parameters, parameter setting and panel operation of the product.


ELC EVR-GHLC-3P/EVR-GHLC-3PP Three-Phase Intelligent Voltage Meter User Manual - cover page
Brand
ELC
Category
Voltage and Current Measurement
Document type
User Manual
Language
Chinese
Pages
6
File format
PDF
File size
260 KB
Published
03 November, 2023
Updated
03 November, 2023
MD5 checksum
F40AED753B1A39EA1971701F4371983A

About this manual

ELC EVR-GHLC-3P and EVR-GHLC-3PP are three-phase intelligent voltage meters with overvoltage, undervoltage, phase loss, phase sequence, and three-phase voltage imbalance detection. They include an internal alarm buzzer and output relays; undervoltage, phase sequence, and imbalance detection are optional, and reset can be automatic or manual.

The manual describes panel operation, parameter settings, terminal wiring, fault codes, and Modbus RTU communication over RS485, including register access and exception codes. This manual is written in Chinese.

What's inside

  • Product functions
  • Technical parameters
  • Parameter settings and debugging
  • Terminal wiring
  • Fault codes
  • Modbus RTU protocol overview
  • Online communication
  • Register access

Specifications

Measurement range (EVR-GHLC-3P)55-500 VAC
Measurement range (EVR-GHLC-3PP)0-500 VAC
Relay action delay0-99.9 s
Output relay contacts2 NO and 2 NC
Output relay capacity7 A/250 VAC or 7 A/30 VDC
Installation35 mm DIN rail
Dimensions107 mm x 93 mm x 59 mm
Weight<400 g
Operating environmentTemperature -20 to 60 C, humidity 10 to 85%
Communication interfaceRS485
Communication distance1000 m maximum
Default baud rate9600 bps

Frequently asked questions

What is the measurement range of the EVR-GHLC-3PP?

The EVR-GHLC-3PP measures 0-500 VAC and requires 85-265 VAC auxiliary power.

How are overvoltage and undervoltage outputs assigned?

Overvoltage uses output relay OUT1, while undervoltage, phase sequence detection, and three-phase imbalance protection share output relay OUT2.

What communication protocol and interface does the meter support?

It supports standard Modbus RTU over an RS485 bus, with up to 32 terminals.

How can a fault be reset manually?

Press the ESC key.

Download PDF (260 KB)

More ELC Manuals