Winsen ZP07-MP503 Air Quality Module User Manual

ZP07 air quality module adopts advanced thin film thick film semiconductor gas sensitive element, the gas sensitive element has extremely high sensitivity to formaldehyde, benzene, carbon monoxide, ammonia, hydrogen, alcohol, cigarette smoke, essence and other gases. The module has been aged, debugged, calibrated and calibrated, with good consistency and extremely high sensitivity. Product features: high sensitivity, excellent long-term stability, factory-calibrated, low power consumption, long life, high cost performance. Main applications: air purifiers, new air ventilation systems, intelligent integrated ceiling, air quality monitoring instruments, exhaust fans, air conditioners, etc.


Winsen ZP07-MP503 Air Quality Module User Manual - cover page
Brand
Winsen
Category
sensor
Document type
User Manual
Language
Chinese
Pages
5
File format
PDF
File size
543 KB
Published
03 November, 2023
Updated
03 November, 2023
MD5 checksum
68BC0AB89BC23F0D27A17E8DCC14E3C9

About this manual

This user manual (version 1.4) describes the Winsen ZP07-MP503 air quality module made by Zhengzhou Winsen Electronic Technology Co., Ltd. The module uses a thick-film semiconductor gas-sensitive element that is highly sensitive to formaldehyde, benzene, carbon monoxide, ammonia, hydrogen, alcohol, cigarette smoke and perfume, and is factory aged, debugged, calibrated and adjusted for good consistency.

The manual lists the module's technical specifications, a structural diagram, sensitivity curves comparing different gases, a typical application diagram, port definitions for the XH2.54-4P terminal, the pollution-level output signal definition, and precautions for installation and use. This manual is written in Chinese.

What's inside

  • Product Description
  • Module Features
  • Main Applications
  • Technical Specifications
  • Sensitivity Curves
  • Application Diagram
  • Port Definitions
  • Output Signal Definition
  • Precautions

Specifications

Detected gasesFormaldehyde, benzene, carbon monoxide, hydrogen, alcohol, ammonia, cigarette smoke, perfume, etc.
Physical interfaceXH2.54-4P terminal
Output data0-10 level pollution signal
Working voltage5.0±0.2 VDC (no reverse-voltage protection)
Output data typeTTL level signal (built-in 200 Ω protection resistor)
Working current≤60 mA
Preheat time≤3 minutes
Response time≤20 seconds
Recovery time≤60 seconds
Operating temperature0-50 °C
Operating humidity≤95% RH
Storage temperature-20 to 60 °C
Storage humidity≤60% RH

Frequently asked questions

What gases can the Winsen ZP07-MP503 air quality module detect?

It detects formaldehyde, benzene, carbon monoxide, hydrogen, alcohol, ammonia, cigarette smoke and perfume, among others.

What is the working voltage of the ZP07-MP503 module?

The module works at 5.0±0.2 VDC without reverse-voltage protection; exceeding 5.5 V causes irreversible damage.

How long does the ZP07-MP503 module need to preheat?

The preheat time is 3 minutes or less, and the manual recommends preheating for more than 5 minutes before first power-on.

What output signal does the module provide?

It outputs a TTL level signal with a built-in 200 Ω protection resistor, encoding pollution levels from 0 to 10.

Download PDF (543 KB)

More Winsen Manuals


View all Winsen manuals →