Introduction to the installation and operation of the ET1280 crimping machine, including specifications and equipment, installation and operating instructions, crimping procedures, calibration, maintenance and crimping machine components.
This manual covers the Eaton ET1280 crimp machine. It includes specifications and equipment, set-up and operating instructions, crimping procedures, calibration, and maintenance, along with descriptions of crimp machine and die cage components.
Safety instructions state that operators must read the manual before operating the equipment, wear safety glasses, and verify correct crimp diameters after crimping. The manual also describes operation with a 110V power unit and with hand pump, air/hydraulic pump, or 12V DC pump models, and the use of a 10,000 psi hydraulic power source.
| Weight (machine only) | 141 lbs. |
|---|---|
| Weight (machine with 110V power unit) | 253 lbs. |
| Pressure rating | 10,000 psi (690 bar) |
| Machine setting range | 000 to 400 |
The pressure rating is 10,000 psi (690 bar).
Settings between 000 and 400 can be achieved with this crimp machine.
No. The manual says never use an extension cord and always plug directly into the power outlet.
The crimper should be mounted onto a workbench that will support a minimum of 300 lbs.