This document introduces the datalink configuration method of Ethernet/IP protocol, which is suitable for CJ2H/CJ2M, CJ1, NS and other devices
This quick guide explains how to configure Ethernet/IP data links between Omron CJ2H/CJ2M PLCs and other devices, using tags or memory addresses. It covers concepts such as tags, tag sets, multicast connections and point-to-point connections.
It describes project setup in CX-Programmer and Network Configurator, device registration, connection creation, tag creation and import, and automatic connection configuration. This manual is written in Spanish.
| Number of connections (CJ2H/CJ2M) | 32 |
|---|---|
| Refresh interval (CJ2H/CJ2M) | 1 to 10000 ms |
| Allowed bandwidth per unit (CJ2H/CJ2M) | 3000 pps |
| Maximum data link per node (CJ2H/CJ2M) | 640 words |
| Maximum tag set size (CJ2H/CJ2M) | 640 words |
A Tag is a name given to an address controlled by the CJ2 and is a network variable.
The CJ1 cannot work with Tags, so memory addresses must be used.
The NS terminal must be version 8.1 or later.
Automatic connections are always Input Only and Multicast.