Best Practice Guide for Industry users of the Customs Connect Facility (CCF) and the Integrated Cargo System (ICS)

This Best Practice Guide is intended to guide high-volume industry users of the Customs Connect Facility (CCF) and the Integrated Cargo System (ICS) with suggestions which will help optimise processing and will improve response times for cargo lodgement, movement and clearance for all users.


Best Practice Guide for Industry users of the Customs Connect Facility (CCF) and the Integrated Cargo System (ICS) - cover page
Category
Other software
Document type
Other
Language
English
Pages
6
File format
PDF
File size
530 KB
Published
01 November, 2023
Updated
01 November, 2023
MD5 checksum
E63C77A338DEEE6F57EDD392F06FEB3D

About this manual

This Best Practice Guide, issued in June 2021, is intended to guide high-volume industry users of the Customs Connect Facility (CCF) and the Integrated Cargo System (ICS). It explains that peak demand normally occurs during core hours between 08:00 and 17:00 Monday to Friday, and that sending large EDI message streams during these times can overload the systems and lengthen response times for cargo lodgement, movement and clearance.

The guide recommends pacing EDI interchanges to no more than 300 messages per minute, keeping interchanges to at most 100 messages, deferring non-urgent messaging and cargo reporting to non-core hours, and checking the Cargo System Status Service (CSSS) before transmission. It also covers reporting Master Air Waybills before House Air Waybills, entering air waybill details accurately, notifying the Department of workload changes, and the scheduled ICS outage windows.

What's inside

  • Introduction
  • Best Practice Guidance
  • Pacing of EDI Interchanges with Single Messages
  • Pacing of EDI Interchanges with Multiple Messages
  • Deferral/bring-forward of non-urgent EDI Messaging
  • Check the Cargo System Status Service before Transmission
  • Changes in Industry Workloads and Timing
  • Change in Business Practice
  • Outages

Specifications

Max single-message transmission rate300 messages per minute (up to 18,000 per hour)
Max messages per interchange100 messages
Max multi-message interchange rate3 interchanges per minute at 100 messages each
Core hours08:00-17:00, Monday to Friday
Application update outage window00:00-04:00 every Wednesday
Systems maintenance outageQuarterly, Saturdays 23:00 to 04:00 Sunday

Frequently asked questions

How fast can I send EDI messages to the ICS?

Interchange transmissions should be limited to no more than 300 individual messages per minute, allowing up to 18,000 messages per hour.

Where can I check the Cargo System Status Service (CSSS)?

The CSSS web service is at https://www.ccf.customs.gov.au/CPS/cargoProcessingStatus.htm and shows queue levels as Green, Orange or Red before you transmit.

When is the ICS shut down for updates?

Application updates occur in a scheduled window of 00:00-04:00 every Wednesday, and systems maintenance outages are quarterly on Saturdays between 23:00 and 04:00 Sunday.

Should I report the Master Air Waybill before the House Air Waybills?

Yes, where both are handled by the same client it is strongly recommended to send the Master Bill first, then the House Bills after a small delay of about 5 minutes.