This document is the user manual for the di-soric LI 200-5-995-1030 T LI Measuring Light Grids. The product is a compact light grid with evaluation electronics. It can be used for measuring and switching or for switching only. The light grids have a horizontal or diagonal beam evaluation and are designed with a compact aluminum housing. They are easy to install and come with the following components: transmitter, receiver, monitoring height H, profile length L, evaluation electronics, and profile cross-section.
di-soric LI 200-5-995-1030 T is a compact measuring light grid with evaluation electronics. It has a 12 x 58 mm aluminum profile, 200 infrared beams, and a 995 mm monitoring height.
Technical data include a 250 to 6,000 mm range, IP 54 protection (IP 65 optional), and connection by a 4.0 m cable. The grid is to be used with LVE, LVX, or LVB evaluation electronics.
| Service voltage | 20 … 26 V DC (see evaluation electronics) |
|---|---|
| Profile cross-section | 12 x 58 mm |
| Dimension X | 17,5 mm |
| Dimension Y | 17,5 mm |
| Profile length | 1.030 mm |
| Housing material | Aluminum (natural) |
| Protection class | III, operation on protective low voltage |
| Evaluation | absolute, percentage, configurable via evaluation electronics |
| Evaluation electronics | external |
| Output function | configurable via evaluation electronics |
| Light source | LED |
| Color | Infrared |
| Wavelength | 880 nm |
| Beam evaluation | via external evaluation electronics |
| Beam separation | 5 mm |
| Number of beams | 200 |
| Monitoring height | 995 mm |
| Range | 250 … 6.000 mm (adjustable via evaluation electronics) |
| Measuring range | 995 mm |
| Ambient temperature during operation | -20 … +40 °C |
| Protection type | IP 54 (IP 65 optional) |
| Connection | Cable, 4,0 m (with plug connector, additional variants on request) |
The light grid includes a transmitter, receiver, monitoring height H, and evaluation electronics.
The light source wavelength is 880 nm.
The protection type is IP 54, with IP 65 optional.
The range is 250 to 6,000 mm and is adjustable via evaluation electronics.
It is to be used with LVE, LVX, or LVB evaluation electronics.