This manual introduces the operation and maintenance of Pulsafeeder pumps. Including troubleshooting guides and technical service policies.
This document is the installation, operation and maintenance manual for the Pulsafeeder OMNI metering pump, document IOM-OM-1104-A. It explains the pump's positive-displacement, mechanically actuated reciprocating diaphragm design, including the pump head, stroke-length control, and gear reducer.
The manual covers equipment inspection; short- and long-term storage; site, piping, and pressure requirements; startup steps such as fastener checks, output adjustment, priming, and calibration; maintenance procedures; spare parts; troubleshooting; accessories; dimensions; and parts drawings and lists. This manual is written in Chinese.
| Pump type | Positive displacement, mechanically actuated reciprocating diaphragm pump |
|---|
The OMNI is a positive displacement, mechanically actuated reciprocating diaphragm pump.
Loosen the locking screw and rotate the handle to change the stroke length.
Storage for less than 12 months is considered short-term storage.
Every 12 months, energize the motor and run the pump for at least one hour with no fluid in the pump head and the inlet and outlet open to atmosphere.