Pulsafeeder PULSAtron Series M Metering Pump Installation Operation and Maintenance Instruction

This manual provides installation, operation, and maintenance instructions for the Pulsafeeder PULSAtron Series M metering pump.


Pulsafeeder PULSAtron Series M Metering Pump Installation Operation and Maintenance Instruction - cover page
Brand
Pulsafeeder
Category
Industrial Supply
Document type
User Manual
Language
English
Pages
30
File format
PDF
File size
2.7 MB
Published
24 October, 2026
Updated
24 October, 2026
MD5 checksum
F8626AEBCA647D0AF226886BE6104DF1

About this manual

The Pulsafeeder PULSAtron Series M metering pumps are positive displacement reciprocating pumps consisting of a power end and a process end separated by a mechanically operated diaphragm. The document serves as an installation, operation, and maintenance instruction bulletin for these pumps.

What's inside

  • Introduction
  • Principles of Operation
  • Equipment Inspection
  • Storage
  • Installation
  • Equipment Startup
  • Maintenance
  • Replacement Parts
  • Troubleshooting
  • Piping Accessories

Frequently asked questions

What is the maximum suction lift capability for fluids with low vapor pressure?

The pump can achieve a wet suction lift of approximately ten feet for fluids with a vapor pressure of 5 psia or less.

What is the minimum required difference between discharge and suction pressure?

The discharge pressure must exceed suction pressure by at least 0.35 Bar or 5 psi to prevent flow through.

How long can a pump be stored indoors before requiring inspection?

Storage for up to twelve months is considered short-term, but longer storage requires inspection and potential part replacement.