This guide covers the installation, operation, and maintenance of the PULSAlarm leak detection system for Pulsafeeder PULSA Series metering pumps.
The PULSAlarm leak detection system is an optional accessory designed for Pulsafeeder PULSA Series metering pumps (models 680, 880, 7120, 7440, 7660, and 8480). It utilizes a dual Teflon diaphragm setup connected to either a vacuum gauge or a pressure gauge to detect leaks. The system operates by maintaining a specific state between the two diaphragms; any damage causing air ingress in vacuum systems or liquid entry in pressure systems triggers an alarm signal.
The factory setting for the vacuum switch is 6 inches of mercury (152mm), while the standard pressure switch setting is 5 PSIG.
Pulsafeeder provides a low viscosity silicone oil as standard, but users may also use water with glycol or propylene glycol, or low viscosity silicone resin/mineral oils.
The system must maintain a vacuum of 650mm mercury column (26 inches) during operation, or it may be re-vacuumed if necessary.