This manual covers the installation, operation, and maintenance of the PULSAlarm leak detection system for PULSA Series metering pumps, including vacuum and…
The PULSAlarm leak detection system is an optional component for PULSA Series metering pumps designed to detect diaphragm damage. It operates using either a vacuum system, which monitors for air leaks between two Teflon membranes, or a pressure system, which uses an intermediate fluid to detect pressure buildup when a membrane fails. The system triggers an alarm or stops the pump upon detecting a fault.
The factory sets the vacuum switch to activate at a reading of 6 inches of mercury.
The standard pressure switch is set to activate at a reading of 5 psig.