This manual contains detailed installation, operation and maintenance instructions for the Pulsafeeder GLM series pumps.
The PULSA GLM metering pump is a positive displacement, mechanically operated reciprocating diaphragm pump. Each pump has a power end and a process end separated by a composite Teflon® diaphragm, and the manual covers installation, startup, maintenance, replacement parts, troubleshooting, piping accessories and dimensional information.
The bulletin is Revision B, dated July 2015, and updates the Introduction and Safety Considerations. It provides installation and operating guidance including location, motor, piping, suction and discharge pressure requirements, output adjustment, priming and calibration.
| Minimum clearance around pump | 3.25 ft (1 m) |
|---|---|
| Lifting requirement | Crane for pumps over 25 kg (55 lb) |
| Recommended suction strainer | 100 mesh screen |
| Mounting | Rigidly bolted to a solid and flat foundation |
It is a positive displacement, mechanically operated reciprocating diaphragm metering pump.
Provide 3.25 ft (1 m) of space around the pump for operation and routine maintenance.
A 100 mesh screen is generally recommended on the suction side.
A crane must be used for all pumps in excess of 25 kg (55 lb).