Winsen MH-441D Methane Gas Sensor User Manual

The MH-441D methane gas sensor is a smart infrared gas sensor that uses non-dispersive infrared principle to detect methane gas in the air. It has good selectivity and is independent of oxygen. The sensor is a small and high-performance sensor that combines mature infrared absorption gas detection technology with micro-mechanical processing and sophisticated circuit design. It is easy to use and can be used directly to replace catalytic combustion components. It is widely used in various occasions where methane and explosive gases are present.


Winsen MH-441D Methane Gas Sensor User Manual - cover page
Brand
Winsen
Category
sensor
Document type
User Manual
Language
Chinese
Pages
5
File format
PDF
File size
313 KB
Published
31 October, 2023
Updated
31 October, 2023
MD5 checksum
38B63C93A390AF859DD1901B410ED5CA

About this manual

The Winsen MH-441D is a general-purpose intelligent infrared gas sensor that detects methane in air using the non-dispersive infrared (NDIR) principle. It offers high sensitivity, low power consumption, fast response, temperature compensation, and UART or analog voltage outputs.

This manual provides product specifications, common measurement ranges and accuracy, pin definitions, analog voltage output instructions, intrinsic safety explosion-proof requirements, installation notes, and usage precautions. This manual is written in Chinese.

What's inside

  • Product Description
  • Sensor Features
  • Main Applications
  • Technical Specifications
  • Common Ranges and Accuracy
  • Product Dimension Drawing
  • Pin Definitions
  • Analog Voltage Output
  • Intrinsic Safety Explosion-proof
  • Precautions

Specifications

Detected gasMethane
Operating voltage3.6~5 V DC
Average current< 85 mA
Measurement range0~10% Vol
Interface level3.0 V
Output signalUART 0.4~2 V
Warm-up time3 min
Response time T90< 30 s
Operating temperature-20~60 ℃
Protection ratingIP54

Frequently asked questions

What detection principle does the Winsen MH-441D use?

It uses the non-dispersive infrared (NDIR) principle to detect methane in air.

What is the measurement range of the MH-441D sensor?

The measurement range is 0 to 10% Vol.

What is the response time of the sensor?

The T90 response time is less than 30 seconds.

What is the protection rating of the MH-441D?

The protection rating is IP54.

Download PDF (313 KB)