Belling BL0910 Multi-phase AC/DC Energy Metering Chip Datasheet

BL0910 is a new multi-phase AC/DC energy metering chip launched by Belling. The chip adopts advanced digital circuit design and mixed signal process, which has high integration, wide power supply voltage range, strong anti-interference ability and easy to use.


Belling BL0910 Multi-phase AC/DC Energy Metering Chip Datasheet - cover page
Brand
Belling
Category
Chips
Document type
Datasheet
Language
Chinese
Pages
81
File format
PDF
File size
2.1 MB
Published
31 October, 2023
Updated
31 October, 2023
MD5 checksum
4A0623D299AF1E0739350BD00C4A4B52

About this manual

The BL0910 is a multi-channel energy metering chip from Belling that can implement up to 10-phase AC/DC energy metering, with 10 current channels sharing one voltage channel. It integrates 11 high-precision sigma-delta ADCs and can measure current, voltage RMS, active power, active energy, fast current RMS for leakage and overcurrent detection, temperature, and waveform data.

The chip provides UART or high-speed SPI output, selectable filters for full-wave, fundamental, or DC RMS and power, built-in waveform registers, anti-creep design, power-down reset below 2.7 V, and an LQFP48 package. It is intended for applications such as 5G base station DC detection modules, data center PDUs, multi-circuit meters, distribution cabinets, and multi-channel fault detection. This manual is written in Chinese.

What's inside

  • Product overview
  • Main features
  • System block diagram
  • Pin arrangement (LQFP48)
  • Electrical performance specifications
  • Operating principle
  • Internal registers
  • Communication interfaces
  • Typical application circuit
  • Package information

Specifications

Energy metering channelsUp to 10 phases (10 currents sharing 1 voltage)
Active energy nonlinearity error<0.1%
Active energy input dynamic range5000:1
RMS measurement dynamic range2500:1
RMS error<0.1%
DC signal measurement dynamic range2000:1
Factory gain error<1%
ADCs11 high-precision sigma-delta ADCs
Current channel inputDifferential, max ±0.7 V; PGA gain x1 to x16
Voltage channel inputDifferential, max ±0.7 V
Temperature sensor range-40 C to 85 C
Leakage monitoringMeasures leakage above 1 mA; fastest response 10 ms
Supply voltage3.3 V
Power consumption40 mW typical
Clock frequencyAbout 8 MHz
Power-down reset thresholdBelow 2.7 V
PackageLQFP48

Frequently asked questions

What is the BL0910 used for?

It is used for 5G base station DC detection modules, data center PDUs, multi-circuit meters for 5G base station macro units, distribution cabinets, and multi-channel fault detection.

How many energy metering channels does the BL0910 provide?

It can implement up to 10-phase AC/DC energy metering, with 10 current channels sharing one voltage channel.

What communication interfaces does the BL0910 provide?

It outputs data through UART or high-speed SPI.

What is the range and accuracy of the built-in temperature sensor?

The built-in temperature sensor measures from -40 C to 85 C with an accuracy of ±2 C.

Download PDF (2.1 MB)

More Belling Manuals