BL0910 is a new multi-phase AC/DC energy metering chip launched by Belling. The chip adopts advanced digital circuit design and mixed signal process, which has high integration, wide power supply voltage range, strong anti-interference ability and easy to use.
The BL0910 is a multi-channel energy metering chip from Belling that can implement up to 10-phase AC/DC energy metering, with 10 current channels sharing one voltage channel. It integrates 11 high-precision sigma-delta ADCs and can measure current, voltage RMS, active power, active energy, fast current RMS for leakage and overcurrent detection, temperature, and waveform data.
The chip provides UART or high-speed SPI output, selectable filters for full-wave, fundamental, or DC RMS and power, built-in waveform registers, anti-creep design, power-down reset below 2.7 V, and an LQFP48 package. It is intended for applications such as 5G base station DC detection modules, data center PDUs, multi-circuit meters, distribution cabinets, and multi-channel fault detection. This manual is written in Chinese.
| Energy metering channels | Up to 10 phases (10 currents sharing 1 voltage) |
|---|---|
| Active energy nonlinearity error | <0.1% |
| Active energy input dynamic range | 5000:1 |
| RMS measurement dynamic range | 2500:1 |
| RMS error | <0.1% |
| DC signal measurement dynamic range | 2000:1 |
| Factory gain error | <1% |
| ADCs | 11 high-precision sigma-delta ADCs |
| Current channel input | Differential, max ±0.7 V; PGA gain x1 to x16 |
| Voltage channel input | Differential, max ±0.7 V |
| Temperature sensor range | -40 C to 85 C |
| Leakage monitoring | Measures leakage above 1 mA; fastest response 10 ms |
| Supply voltage | 3.3 V |
| Power consumption | 40 mW typical |
| Clock frequency | About 8 MHz |
| Power-down reset threshold | Below 2.7 V |
| Package | LQFP48 |
It is used for 5G base station DC detection modules, data center PDUs, multi-circuit meters for 5G base station macro units, distribution cabinets, and multi-channel fault detection.
It can implement up to 10-phase AC/DC energy metering, with 10 current channels sharing one voltage channel.
It outputs data through UART or high-speed SPI.
The built-in temperature sensor measures from -40 C to 85 C with an accuracy of ±2 C.