The datasheet of BL0906 six-phase AC/DC energy metering chip provides a detailed introduction to the product, including product overview, basic features, system diagram, pin arrangement, performance indicators, working principles, etc.
BL0906 is a multi-channel energy metering chip from Belling for up to six-phase AC/DC energy metering. It integrates seven high-precision Sigma-Delta ADCs to measure six currents and one voltage, and can output current and voltage RMS, active power, active energy, fast current RMS, temperature, and waveform data through UART or SPI.
Key characteristics include active energy nonlinearity error below 0.1% within a 5000:1 input dynamic range, RMS error below 0.1% within a 2500:1 range, selectable DC measurement, leakage monitoring above 1 mA, per-channel overcurrent indication, a built-in temperature sensor from -40 to 85 C, and single 3.3 V operation at 30 mW typical in an LQFP32 package. This manual is written in Chinese.
| Measurement channels | 6 current channels and 1 voltage channel |
|---|---|
| Active energy nonlinearity error | <0.1% within 5000:1 input dynamic range |
| RMS measurement error | <0.1% within 2500:1 input dynamic range |
| DC measurement | 2000:1 input dynamic range; energy nonlinearity error <±1% |
| Leakage monitoring | Measures leakage above 1 mA; shortest response 10 ms |
| Temperature sensor | -40 to 85 C, ±2 C accuracy |
| Supply and power | 3.3 V single supply; 30 mW typical |
| Package | LQFP32 |
| Internal reference voltage | 1.097 V |
It has six current channels and one voltage channel.
It supports UART and SPI interfaces.
Typical power consumption is 30 mW with a single 3.3 V supply.
The built-in temperature sensor covers -40 to 85 C with ±2 C accuracy.